Laboratory Centrifuge model NEYA 5/NEYA 5C is suitable for Blood & Urine sample analysis in Hospital & Pathology. The versatile Hybrid Rotor provides super flexibility of Swing out & Fixed angle in same Rotor with 15ml & 50ml Conical & Blood Collection Tubes.
Salient Features
- Compact and light weight
- Fixed and swing out angle (HYBRID) rotor for various applications
- MICRO controller with digital display
- Digitally controlled ACCELERATION and DECELERATION Profiles and braking
- Automatic Imbalance detection
- Emergency lid lock release
- Lid opening on pressing key
- Last set parameters recall (useful for repetitive analysis)
- Built according to EUROPEAN DIRECTIVES
| Technical Specifications | ||
| Model | Neya 5C | Neya 5 |
| Display | LED | LCD |
| Maximum capacity |
8 x 15 ml (Fixed & Swing-out angle) 4 x 50 ml (Fixed & Swing-out angle) |
|
| Maximum speed / RCF |
4700 rpm / 3350g (Fixed angle) 4700 rpm / 3560g (Swing-out) |
|
| Rotor type | Hybrid | |
| Setting RPM |
Yes (From 200 to 4700 rpm in 10 rpm steps) |
Yes (From 200 to 4700 rpm in 10 rpm steps) |
| Setting RCF | No |
Yes (10g to 3350g Fixed angle in 10g steps) (10g to 3560g Swing-out angle in 10g steps) |
| Display RCF | Yes | |
| Timer |
01 to 99 (min) and continuous mode |
00:30 to 99:50 (min:ss) and continuous mode |
| Date and Time | - | Yes |
| Acceleration levels | - | L-M-H (Low - Medium - High) |
| Deceleration levels | Low & High | L-M-H-0 (Low - Medium - High - Coasting) |
| Spin function | No | Yes |
| Programs | - | 5 |
| Calibration window on lid for speed | ✓ | ✓ |
| Control Communication | Digital | Digital |
| Self-Diagnostic of error | ✗ | ✓ |
| Parameters setting switches | Feather Touch Keys | |
| Brushless motor with frequency drive | ✓ | ✓ |
| Inverter fault detection with auto shut down | ✓ | ✓ |
| Last set parameters recall | ✓ | ✓ |
| Motor overload protection | ✓ | ✓ |
| Auto lid opening after cycle | ✗ | ✓ |
| Emergency lid lock release | ✓ | ✓ |
| Imbalance detection with centrifugation cut off | ✓ | ✓ |
| Noise | ≤ 55 dB | |
| External Dimensions W x D x H | 360 × 465 × 300 MM | |
| Weight | 23.5 kg | |
| Directive / Standard | IEC 61010-1 ; IEC 61010-2-020, IEC 61010-2-101, IEC 61326-1 | |
Supply: 220-240 Volts, 50 Hz Single Phase.
| Technical Specifications | ||
| Model | Neya 5C | Neya 5 |
| Display | LED | LCD |
| Maximum capacity |
8 x 15 ml (Fixed & Swing-out angle) 4 x 50 ml (Fixed & Swing-out angle) |
|
| Maximum speed / RCF |
4700 rpm / 3350g (Fixed angle) 4700 rpm / 3560g (Swing-out) |
|
| Rotor type | Hybrid | |
| Setting RPM |
Yes (From 200 to 4700 rpm in 10 rpm steps) |
Yes (From 200 to 4700 rpm in 10 rpm steps) |
| Setting RCF | No |
Yes (10g to 3350g Fixed angle in 10g steps) (10g to 3560g Swing-out angle in 10g steps) |
| Display RCF | Yes | |
| Timer |
01 to 99 (min) and continuous mode |
00:30 to 99:50 (min:ss) and continuous mode |
| Date and Time | - | Yes |
| Acceleration levels | - | L-M-H (Low - Medium - High) |
| Deceleration levels | Low & High | L-M-H-0 (Low - Medium - High - Coasting) |
| Spin function | No | Yes |
| Programs | - | 5 |
| Calibration window on lid for speed | ✓ | ✓ |
| Control Communication | Digital | Digital |
| Self-Diagnostic of error | ✗ | ✓ |
| Parameters setting switches | Feather Touch Keys | |
| Brushless motor with frequency drive | ✓ | ✓ |
| Inverter fault detection with auto shut down | ||
| Last set parameters recall | ✓ | ✓ |
| Motor overload protection | ||
| Auto lid opening after cycle | ✗ | ✓ |
| Emergency lid lock release | ||
| Imbalance detection with centrifugation cut off | ✓ | ✓ |
| Noise | ≤ 55 dB | |
| External Dimensions W x D x H | 360 × 465 × 300 MM | |
| Directive / Standard | IEC 61010-1 ; IEC 61010-2-020, IEC 61010-2-101, IEC 61326-1 | |
Supply: 220-240 Volts, 50 Hz Single Phase.