REMI, with over 65 years of manufacturing experience, combined with European design and style, makes a perfect combination to develop and present the whole range of “NEYA” centrifuges with performance and characteristics suitable for all the operational needs of modern laboratories.
It is with these premises, we are pleased to present “NEYA” Range of ventilated and Refrigerated Centrifuges.
| Salient Features / Technical Data | ||||||||
| Model | NEYA-8 | NEYA-10 | NEYA-16 | NEYA-10R | NEYA-16R | |||
| Maximum Capacity | 4 × 175 ml (swing out) – 6 × 100 ml (fixed angle) | |||||||
| Maximum Speed | 4500 rpm (swing out) 6000 rpm (fixed angle) |
4500 rpm (swing out) 6000 rpm (fixed angle) |
4500 rpm (swing out) 16000 rpm (fixed angle) |
4500 rpm (swing out) 6000 rpm (fixed angle) |
4500 rpm (swing out) 16000 rpm (fixed angle) |
|||
| Setting RPM | Yes | |||||||
| Setting RCF | - | Yes | ||||||
| Display RCF | Yes | Yes | ||||||
| Timer | 00:30 to 99:50 (mm:ss) and continuous mode | |||||||
| Date and Time | Yes | Yes | ||||||
| Acceleration Levels | L-M-H (Low - Medium - High) | 0-9 (0 = min - 9 = max) | ||||||
| Deceleration Levels | L-M-H (Low - Medium - High) | 0-9 (0 = min - 9 = max) | ||||||
| Temperature Range (Settable) | - | - | - | -10°C to +40°C | ||||
| Precool Function | - | - | - | Yes | ||||
| Display Temperature | - | - | - | Yes (°Cand°F) | ||||
| Spin Function | - | Yes | ||||||
| Programs | - | 10 programs with protection function | ||||||
| Indicators of Rotor | Yes | |||||||
| Calibration Window on lid for speed | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Display | LCD | LCD | LCD | LCD | LCD | |||
| Control Communication | Digital | Digital | Digital | Digital | Digital | |||
| Self-Diagonostic of error | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Parameters setting switches | Feather Touch Keys & Bi-Directional encoder | |||||||
| Brushless motor with frequency drive | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Inverter fault detection with auto shut down | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| CFC free refrigeration system | × | × | × | ✓ | ✓ | |||
| Last set parameters recall | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Choice of rpm / rcf setting | RPM | RPM / RCF | RPM / RCF | RPM / RCF | RPM / RCF | |||
| Automatic Rotor Identification | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Motor overload protection | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Emergency lid lock release | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Imbalance detection with centrifugation cut off | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Gas Hinge to prevent door falling | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Noise | ≤ 55 dB | |||||||
| External Dimensions (W×D×H) / Weight | 450 × 590 × 330 mm / 40 kg | 730 × 640 × 330 mm / 70 kg | ||||||
| Directive / Standard | IEC 61010-1 ; IEC 61010-2-020 | |||||||
| Recommended Voltage Stabilizer | - | - | - | VS-02 | ||||
| Optional | Motorised Lid Lock | |||||||
Supply: 220-240 Volts 50 Hz Single Phase.