REMI Neya 12 & Neya 12R with European design is a perfect combination of performance & characteristics.
REMI Neya 12 & Neya 12R (Refrigerated) centrifuge are designed considering the specific requirements of medical laboratories.
Precise control of all run parameters helps in efficient results for sensitive diagnostic tests. Wide choice of rotor heads and adaptors makes these bench top centrifuges truly versatile.
Salient Features
- Brush less motor with variable frequency drive, maintenance free
- Microprocessor controller with multicolor backlit LCD display
- 10 program memory with password protection
- 10 Acceleration and 10 deceleration profiles
- Fast spin feature for quick run
- Choice of RPM / RCF setting and display
- Automatic rotor detection
- Countdown timer 30 seconds to 99 minutes
- Imbalance detection system with automatic stop function
- Door interlocking system
- Emergency lid opening in case of power failure
- Last program recall
- LED indication to see status of centrifugation from a distance
- Stainless steel centrifugation bowl with armoured chamber
- Comfortable height for an easy access
- Sophisticated anti vibration system
- Construction in accordance with European directives
- No puller required for rotor removal
- Hydraulic hinges for soft touch lid opening & closure
| Technical Specifications | |||
| Features | NEYA-12 | NEYA-12R | |
| Maximum capacity | 4 x 175 ml (swing out) - 6 x 100 ml (fixed angle) | ||
| Maximum speed | 4500 rpm (swing out) - 16000 rpm (fixed angle) | ||
| Setting RPM | Yes | Yes | |
| Setting RCF | Yes | Yes | |
| Display RCF | Yes | Yes | |
| Timer | 00:30 to 99:50 (mm:ss) and continuous mode | ||
| Date and Time | Yes | Yes | |
| Acceleration levels | 0-9 (0 = min - 9 = max) | ||
| Deceleration levels | 0-9 (0 = min - 9 = max) | ||
| Temperature range (Settable) | - | -10°C to +40°C | |
| Precool function | - | Yes | |
| Display temperature | - | Yes (°C and °F) | |
| Spin function | Yes | Yes | |
| Programs | 10 programs with protection function | ||
| Indication of rotor | Yes | Yes | |
| Calibration window on lid for speed | ✓ | ✓ | |
| Display | LCD | LCD | |
| Control Communication | Digital | Digital | |
| Self-Diagnostic of error | ✓ | ✓ | |
| Parameter setting switches | Feather Touch Keys & Bi-Directional encoder | ||
| Brushless motor with frequency drive | ✓ | ✓ | |
| Inverter fault detection with auto shut down | ✓ | ✓ | |
| CFC free refrigeration system | × | ✓ | |
| Last set parameters recall | ✓ | ✓ | |
| Choice of RPM / RCF setting | RPM / RCF | RPM / RCF | |
| Automatic Rotor Identification | ✓ | ✓ | |
| Motor overload protection | ✓ | ✓ | |
| Emergency lid lock release | ✓ | ✓ | |
| Imbalance detection with centrifugation cut off | ✓ | ✓ | |
| Gas Hinge to prevent door falling | ✓ | ✓ | |
| Noise | ≤ 55 dB | ≤ 55 dB | |
| External dimensions (W x D x H) / Weight | 450 x 590 x 330 mm / 40 Kg | 730 x 640 x 330 mm / 70 Kg | |
| Directive / Standard | IEC 61010-1 : IEC 61010-2-020 | IEC 61010-1 : IEC 61010-2-020 | |
| Recommended Voltage Stabilizer | - | VS-02 | |
Supply: 220-240 Volts, 50 Hz Single Phase.
Nomenclature method of Rotors & accessories
| Alphabets in beginning | Numbers in middle | Alphabets at end |
| A – Fixed angle rotor | 1st numeral – Quantity per insert | C – Conical tube |
| S – Swing out rotor | 2nd numeral – Tube capacity (ml) | R – Round bottom tube |
| B – Bucket | L – Long tube | |
| I – Insert for bucket | S – Short tube | |
| C – Cushion | ||
| RE – Reducer | ||
| HE – Haematocrit Rotor |
| Examples Description | |
| S 4-175 | (Swing out Rotor, 4 tubes of 175 ml capacity) |
| A 32-15N | (Angle Rotor, 32 tubes of 15 ml capacity) |
| B 2-50 F | (Bucket, 2 tubes of 50 ml capacity, Conical) |
| I 1-50 R | (Insert, 1 tube of 50 ml capacity round bottom) |
| C 15F | (Cushion for 15 ml Conical) |
| RE 15-5/7 | (Reducer from 15ml to 5/7 ml tube) |